Technical Data
Specs, manuals, videos, and product documents
Loading technical data…
Volume rewards
Example: a $10,000 BRAVO order saves $1,000 automatically.
| Qualifying subtotal | $5K | $10K | $15K | $50K |
|---|---|---|---|---|
| BRAVO | 5% | 10% | 13% | 15% |
| Other eligible brands | 3% | 5% | 6% | 8% |
The highest eligible tier is applied automatically to qualifying regularly priced merchandise.
Important: Bulk discounts cannot be combined with products that already have a current discount, sale price, or other promotional offer.
Click image to zoom
Recommended Add-Ons
Loading recommended accessories…
CLICK TO CALL US 737-738-6329 FOR ANY QUESTIONS
The Olivia Midnight Series Single Zone Ductless Mini Split Systems we offer have options of 16ft, 25ft, and 50ft kits. Has a sleek black design that offers a distinguished and sharp look and feel. Paired with style and innovative features. Auto-swing horizontal louvers maintain even airflow throughout the room, and the Genius Core Technology enables the unit to operate with an ultra-low compressor speed of 12Hz for extra energy savings, granting them a high-efficiency rating of up to 26.4 SEER2. This system will both heat and cool your home or office effectively down to -13°F for Standard units, and even down to -22°F for Hyper units.
The units can be controlled with the Cooper&Hunter remote control, or via a smart device when used with the optional Wi-Fi kit and Cooper&Hunter Remote app. Other notable features include Follow Me Mode, Sleep Mode, Timer options, and 46°F Freeze Protection. The Olivia indoor wall-mounted series is an incredible option as a single or multi-zone mini split unit!
Cooper & Hunter Single Zone Ductless Mini Split System (24,000 BTU Inverter with Heat Pump)
Outdoor Unit: 24,000 BTU (1pc) – Model: CH-RES24-230VO
Indoor Unit: 24,000 BTU (1pc with remote) – Model: CH-RB24MOLVWM-230VI
Wi-Fi Adapter
Optional Installation Kit (16ft, 25ft, or 50ft options available) Must be selected above.
Wireless Remote Control
Installation Manual
User's Manual
Manufacturer Warranty
All units must be installed by a licensed HVAC professional for the warranty to be valid. Registration is required within 60 days of installation and can be completed online or by phone. The installation kit is necessary for the system to function. Ensure that you have selected the desired installation kit above. This kit comes with Pre-Flared 99% Copper Lines, Data Communication Wires, PVC Drainage Attachment, Wrapping Bands, etc.
| Capacity | Standard Models (Midnight) | HYPER Models (Midnight) | Voltage |
|---|---|---|---|
| 9,000 BTU | CH-RB09OLVWM-115VI + CH-RES09-115VO | - | 115V |
| 12,000 BTU | CH-RB12OLVWM-115VI + CH-RES12-115VO | - | 115V |
| 6,000 BTU | CH-RB06MOLVWM-230VI + CH-RHP06F9-230VO | 230V | |
| 9,000 BTU | CH-RB09MOLVWM-230VI + CH-RES09-230VO | CH-RB09MOLVWM-230VI + CH-RHP09-230VO | 230V |
| 12,000 BTU | CH-RB12MOLVWM-230VI + CH-RES12-230VO | CH-RB12MOLVWM-230VI + CH-RHP12-230VO | 230V |
| 18,000 BTU | CH-RB18MOLVWM-230VI + CH-RES18-230VO | CH-RB18MOLVWM-230VI + CH-RHP18-230VO | 230V |
| 24,000 BTU | CH-RB24MOLVWM-230VI + CH-RES24-230VO | CH-RB24MOLVWM-230VI + CH-RHP24-230VO | 230V |
| Indoor Model | CH-RB24MOLVWM-230VI | ||
|
Power Supply
|
Rated | V, Ph, Hz | 208/230, 1, 60 |
| Rated Capacity | Btu/h | 24,000 | |
| Minimum Circuit Ampacity (MCA) | A | 3 | |
| Max. Fuse | A | 15 | |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | CFM | 759.3/588.6/459.1/382.6 | |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | CFM | 54.0/48.5/43.5/27.5/20.5 | |
|
Indoor
|
Dimensions | inch | 42.60x9.21x13.27 |
| Packing | inch | 45.47x12.40x16.34 | |
| Net/Gross Weight | lbs. | 30.86/40.56 | |
|
Room temperature
|
Cooling | °F | 60 – 90 |
| Heating | °F | 32 – 86 | |
| Outdoor Model | CH-RES24-230VO | ||
|
Power Supply
|
Rated | V, Ph, Hz | 208/230, 1, 60 |
| Voltage Range | V | 187-253 | |
|
Cooling
|
Rated Capacity (Range) | Btu/h | 9,700-27,000 |
| Rated Current | A | 10 | |
| EER2 | Btu/h | 13 | |
| SEER2 | Btu/h | 23.5 | |
|
Heating at 47°F
|
Rated Capacity (Range) | Btu/h | 11,300-32,700 |
| Rated Current | A | 10.4 | |
| COP | W/W | 3.08 | |
| HSPF4 | 11 | ||
| HSPF5 | 7.7 | ||
| Heating at 17°F (AHRI) | Btu/h | 21,300 | |
| Minimum Circuit Ampacity | A | 24 | |
| Max. Fuse (Outdoor Unit) | A | 25 | |
| Outdoor Air Flow (Max.) | CFM | 2,235.30 | |
| Outdoor Noise Level (Sound Pressure) | dB(A) | 60 | |
| Dimension (W×D×H) | inch | 37.24x16.14x31.89 | |
| Packing (W×D×H) | inch | 42.91x19.69x34.84 | |
| Net/Gross Weight | lbs. | 122.13/132.28 | |
| Refrigerant Type / Charge | oz. | R454B/70.55 | |
| Refrigerant Precharge Length | ft. | 25 | |
| Additional Charge for Each ft. | oz/ft | 0.32 | |
| Design Pressure | PSIG | 550/340 | |
| Refrigerant Piping Liquid Side/Gas Side | inch | 3/8"/5/8" | |
| Max. Pipe Length | ft. | 164 | |
| Max. Difference in Level | ft. | 82 | |
|
Ambient Temperature
|
Cooling | °F | -13~122 |
| Heating | °F | -13~75 | |
|
Certifications
|
ETL | TRUE | |
| AHRI | TRUE | ||
| Energy Star for Cold Climate | TRUE | ||
| NEEP | TRUE | ||
Technical Data
Loading technical data…
Product FAQs
On compatible systems, the app can provide remote on and off control, temperature adjustment, operating-mode selection, fan-speed control, daily or weekly scheduling, customized sleep settings, and an error-code check function. Available features can vary by model and app version.
Yes. Cooper & Hunter states that multiple users can connect and share control of compatible zones or units through the Cooper & Hunter Remote app, which can be useful for households, offices, and multi-zone installations.
Use the exact model number from the equipment label to search Cooper & Hunter’s website or support center. Confirm that the indoor unit, outdoor unit, voltage, capacity, and series shown in the result match the equipment before relying on the manual, submittal, leaflet, or troubleshooting material.
Yes. Cooper & Hunter’s support center allows installers to sign in or register for a personal account to access troubleshooting resources. Warranty diagnosis may still require direct troubleshooting with a Cooper & Hunter Technical Support agent while the technician is on site.
Yes. Cooper & Hunter’s Limited Warranty states that qualifying equipment must be properly installed by a state-certified or licensed HVAC contractor in accordance with applicable codes, permits, manufacturer instructions, and accepted trade practices.
Cooper & Hunter provides product manuals, troubleshooting guides, warranty information, product-specific documents, and selected troubleshooting videos through its official support center. Search using the exact model number to avoid using instructions for a different system.
Yes. Cooper & Hunter’s official website includes a Find Solution tool for selecting a system by application and climate zone, along with a dealer locator. Final equipment selection should still be confirmed against the project load, electrical requirements, installation conditions, and the exact product documentation.
Use Cooper & Hunter’s official Rebates & Incentives portal and enter the requested location and equipment information. Eligibility depends on the exact model, efficiency requirements, installation details, utility program, tax rules, and customer location.
No. Cooper & Hunter states that its systems meet guidelines in many regions and may qualify for rebates or other incentives, but availability and approval depend on the local program and the exact equipment. Verify eligibility before treating an incentive as part of the final project cost.
Compatible systems use the Cooper & Hunter Remote app, available through the Apple App Store and Google Play. The exact system must support Wi-Fi control and may require the manufacturer’s compatible wireless module or smart kit.
No. Cooper & Hunter’s Smart Kit instructions state that the reserved interface is intended for the manufacturer-provided compatible wireless module. Power should be disconnected before installation, and access, replacement, and maintenance of the wireless module should be handled by qualified personnel.
For the eligible product categories listed on its warranty page, Cooper & Hunter publishes one year of coverage for the original remote control, five years on parts, and seven years on the compressor for the original registered end user. Exact coverage can vary by product, purchase channel, registration status, and program eligibility, so confirm the warranty for the exact model.
The product owner or servicing technician should contact Cooper & Hunter Technical Support. For warranty troubleshooting, Cooper & Hunter instructs that the technician should be on site so the support agent can review error codes, symptoms, electrical readings, mechanical measurements, and other diagnostic information.
Have the unit model and serial number, installation date, installer’s EPA or HVAC license information, and the place of purchase available. Cooper & Hunter may also request photographs, error codes, measurements, or other diagnostic details before processing warranty support.
Yes. Cooper & Hunter’s support center states that one-on-one technical and warranty assistance is available in English, Spanish, Mandarin, Russian, and Ukrainian.
Cooper & Hunter lists Technical Support at (888) 293-9252 and an additional number at (786) 953-6706. Its support center currently lists availability Monday through Friday from 9:00 AM to 8:00 PM Eastern Time. Check the official support page for current hours before calling.
Cooper & Hunter’s published policy excludes labor and related field costs. It also states that refrigerant, charging, recharging, adjustment, and removal costs are not covered. The owner is generally responsible for these expenses even when an eligible replacement part is provided.
Register the equipment through Cooper & Hunter’s official warranty registration process. Registration can be completed online or by phone. Keep the model and serial numbers for each piece of equipment, the installation and purchase details, and the installing contractor’s information available before starting.
Cooper & Hunter states that products should be registered within 60 days of installation for its Limited Warranty. Registration and coverage remain subject to the current warranty policy and the eligibility requirements for the specific product.
Cooper & Hunter requests the model and serial number for each piece of equipment, installation date, owner contact information, installer or dealer information, purchase details, an email address, and the HVAC license number. Much of this information should be available on the product labels and installation invoice.
Yes. Cooper & Hunter’s published policy states that warranty coverage applies to products remaining at their original installation location. Equipment removed and reinstalled elsewhere may be excluded from warranty coverage.
Yes. Cooper & Hunter lists damage or repairs arising from non-compatible parts, third-party components, alterations, modifications, or improper applications among its warranty exclusions. Use components approved for the exact equipment and application.
Cooper & Hunter’s published Limited Warranty is provided to the first original owner at the original installation location and is not transferable to subsequent owners. Review the current warranty policy for the exact product and transaction.
No. Wi-Fi and app compatibility are model dependent. Some systems include compatible wireless capability, while others require a specific Cooper & Hunter Wi-Fi accessory or do not support app control. Confirm the exact model’s product documents and accessory compatibility before ordering.