You have no items in your shopping cart.
0item(s)
You have no items in your shopping cart.
IMPORTANT: THIS IS ONLY ONE PART OF THE SYSTEM. TO HAVE A FULLY FUNCTIONING SETUP, YOU MUST ALSO PURCHASE A COMPATIBLE [INDOOR/OUTDOOR] UNIT.
NOTE: The default selection does not include an Installation Kit. Upgrade your selection to add to your order.
IMPORTANT: THIS IS ONLY ONE PART OF THE SYSTEM. TO HAVE A FULLY FUNCTIONING SETUP, YOU MUST ALSO PURCHASE A COMPATIBLE [INDOOR/OUTDOOR] UNIT.
The Cooper&Hunter Universal Floor/Ceiling units provide a versatile cooling and heating solution, suitable for both ceiling and wall installations. These units are engineered for flexibility, allowing placement horizontally on ceilings or vertically on walls to meet diverse architectural needs.
Available in capacities of 18K, 24K, 36K, 48K, and 60K BTU/h, these systems are designed for both single-zone and multi-zone applications, offering high efficiency with ratings of up to 23 SEER. This adaptability makes them perfect for various settings, from residential to commercial spaces.
The installation is streamlined and discreet, ensuring the units blend seamlessly into any environment without compromising interior aesthetics. Additionally, these systems can operate efficiently in extreme conditions, heating effectively in ambient temperatures as low as -13°F for standard units and up to -22°F for Hyper Units.
Control options include a remote control and wall thermostat enhancing user comfort and ease of use. These features, combined with their flexible installation options, make the Universal Floor/Ceiling units an excellent choice for those seeking efficient and adaptable heating and cooling solutions.
All units must be installed by a licensed HVAC professional for the warranty to be valid. Registration is required within 60 days of installation and can be completed online or by phone. The installation kit is necessary for the system to function. Ensure that you have selected the desired installation kit above. This kit comes with Pre-Flared 99% Copper Lines, Data Communication Wires, PVC Drainage Attachment, Wrapping Bands, etc.
Capacity | BTU | SKU |
Dual (2) Zone: | 18,000 BTU | CH-18MES-230VO |
Dual/Tri (2 or 3) Zone: | 28,000 BTU | CH-28MES-230VO |
Dual/Tri/Quad (2, 3 or 4) Zone: | 36,000 BTU | CH-36MES-230VO |
Dual/Tri/Quad/Pent (2, 3, 4 or 5) Zone: | 48,000 BTU | CH-48MES-230VO |
Dual/Tri/Quad/Pent (2, 3, 4 or 5) Zone: | 55,000 BTU | CH-55MES-230VO |
Capacity | BTU | SKU |
Dual (2) Zone: | 19,000 BTU | CH-HPR19M-230VO |
Dual/Tri (2 or 3) Zone: | 28,000 BTU | CH-HPR28M-230VO |
Dual/Tri/Quad (2, 3 or 4) Zone: | 36,000 BTU | CH-HPR36M-230VO |
Dual/Tri/Quad/Pent (2, 3, 4 or 5) Zone: | 48,000 BTU | CH-HPR48M-230VO |
Dual/Tri/Quad/Pent (2, 3, 4 or 5) Zone: | 55,000 BTU | CH-HPR55M-230VO |
The capacity and number of systems can vary for each outdoor unit. Consult the combination chart for potential loading configurations. Ensure the total capacity of all connected indoor units aligns with the minimum and maximum loading range of the selected outdoor unit. It is not mandatory to utilize all circuits on an outdoor unit; some circuits may remain sealed without an attached indoor unit.
Our sales team meticulously reviews every order and will promptly contact you to make any necessary adjustments. For guidance in selecting the correct combination of indoor units, please contact us directly or refer to the Combination Chart provided above or located in the Custom tab.
Specification | Details |
System type |
Single/Multi-zone unit
|
BTU Rated | 18,000 |
Power source |
208-230V, 1Ph, 60Hz
|
Dehumidification value (pnt/day) | 4.63 |
Refrigerant type | R410A |
Voltage range (V) | 187-253 |
Packing dimensions (WxDxH) |
45.08x29.72x12.52
|
Controller |
RG10K-exclusive remote & 120X or 120N wire controller
|
Refrigerant piping Liquid/Gas side (inch) | 1/4"/1/2" |
EER2 | 12.5 |
SEER2 | 23 |
Unit Net/Gross weight |
57.10/68.34
|
Unit dimensions (W*H*D) |
42.05x26.57x9.25
|
Operation Range - Heating | 32~86 |
Operation Range - Cooling | 62~90 |
Minimum circuit ampacity | 1.9 |
Max. fuse | 15 |
Indoor Noise Level H/M/L | 45.5/43/39 |
Indoor Air Flow |
582.7/548.24/485.29/420.59
|
Drainage water pipe diameter | 1" |
Versatile Installation: Cooper&Hunter Universal Floor/Ceiling units are engineered for both ceiling and wall installations, capable of being placed horizontally or vertically to meet diverse architectural demands.
Broad Capacity Range: Available in 18K, 24K, 36K, 48K, and 60K BTU/h, these systems accommodate single-zone and multi-zone applications, making them suitable for both residential and commercial spaces.
High Efficiency: With an impressive SEER rating of up to 25, these units offer top-tier energy efficiency, reducing operational costs and environmental impact.
Streamlined and Discreet Design: The units are designed to integrate seamlessly into any setting, ensuring a discreet presence that does not disrupt interior aesthetics.
Extreme Weather Operation: Capable of operating effectively in ambient temperatures as low as -13°F for standard units and -22°F for Hyper Units, ensuring reliable heating even in harsh conditions.
Flexible Control Options: Control these units via remote control or wall thermostat, providing ease of use and enhanced user comfort.
Adaptable and Efficient: The flexibility in installation and control, combined with high efficiency and robust operation in various conditions, makes the Universal Floor/Ceiling units a prime choice for efficient and adaptable heating and cooling solutions.
We will prepare your order within 24 hours if it’s received on a weekday (before noon). Orders are shipped in one to two business days. Transit time is between 3 to 6 business days, although exceptions apply. We email tracking information once your purchase is shipped.
IMPORTANT DELIVERY INFORMATION: Please be kindly informed that this air conditioner, due to its weight and shipping restrictions, is shipped palletized with an arranged freight service and requires an appointment for delivery. To AVOID delays, please check if the provided phone number in the order details is a current number where you can be reached. You can also contact the carrier directly and refer to your tracking number to set up a date and time for your appointment. It is your responsibility to ensure a safe and secure environment for delivery. Please note that we cannot be held liable for any packages that are stolen or lost after delivery has been confirmed. PLEASE verify your shipping address, as changes to the address after freight has shipped can result in an additional 15% or higher fee depending on freight weight and dimensions.
SMALLWARES INFORMATION: Please be informed that for smaller items, such as Installation Kits, Smart Connectivity Dongles, and TTW Sleeves, when these items are ordered individually, they may be shipped via FedEx without a signature requirement. It is your responsibility to ensure a safe and secure environment for delivery. Please note that we cannot be held liable for any packages that are stolen or lost after delivery has been confirmed. Thank you for your understanding and cooperation.
INSPECT YOUR MERCHANDISE BEFORE SIGNING: Please inspect your boxes thoroughly when you receive them. They should arrive shrink-wrapped and on a pallet. If you notice any damages or imperfections (e.g. crushed box or forklift hole), please write comments on the receipt before signing for delivery, no matter how small damages seem. Contact us immediately to assist you.