Free ShippingOver $300 on select brands
Great DiscountsCompetitive deals on top HVAC brands
Financing AvailableAs low as $243.91/mo
30-Day Return LimitReturns accepted within 30 days
Customer SupportWe're here to help
Home Hyper Heat 2nd Gen Series
Hyper Heat 2nd Gen Series

MRCOOL 48K Hyper Heat Central Ducted Heat Pump Condenser | R-454B – CENTRAL-48-HP-C-230B00-O

SKU CENTRAL-48-HP-C-230B00-O Air Conditioner Condenser Units16.5 SEER2208-230V
$2,927.00
In StockShips in 1-2 business days
High efficiency. Quiet performance. Easy installation.

A smart, reliable choice for year-round comfort.

Best for:
  • Bedrooms
  • Home Offices
  • Additions
  • Garages
See specs
Cooling
See specs
Heating
See specs
Quiet Inside
Efficient
High Efficiency

Brand Information

MrCool
Support Number
(270)366-0457
Product Overview Full product description Read the longer product copy, features, and application notes.
MRCOOL — Wall Mount

MRCOOL 48K Hyper Heat Central Ducted Heat Pump Condenser | R-454B – CENTRAL-48-HP-C-230B00-O

CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS

CLICK TO CALL US 737-738-6329 FOR ANY QUESTIONS

MRCOOL 48K Hyper Heat Central Ducted Heat Pump Condenser | R-454B – CENTRAL-48-HP-C-230B00-O

Summary

The 48K MRCOOL® Hyper Heat Central Ducted Condenser is crafted to provide outstanding performance in even the most extreme climates, from icy winters to scorching summers. This Hyper Heat system utilizes DC Inverter technology and variable speed functionality to deliver consistent, high-quality operation. With a SEER2 rating of up to 16.5 and an HSPF2-4 rating of up to 9.5, it offers powerful heating and cooling while maximizing energy efficiency. A MRCOOL® Smart thermostat is included, giving you complete control over your indoor environment with ease. The 48K MRCOOL® Hyper Heat Central Ducted Condenser is compatible with the 48K MRCOOL® VersaPro® Central Ducted Air Handler. The air handler is built for flexibility, supports various installation options, and is compatible with an optional heat kit for added capability. The system features R-454B refrigerant, a sustainable choice that minimizes its impact on the environment. Durability is a hallmark of the outdoor heat pump, constructed with a painted galvanized steel exterior for long-term resilience. The air handler is thoughtfully designed with a compact form, slide-out blower, and self-diagnostic panel to streamline maintenance and troubleshooting. Enjoy peace of mind with the system’s 10-year warranty, covering the compressor, parts, and labor. The labor warranty activates automatically upon installation, so no registration is required. Enhance your home’s comfort with the efficient and reliable 48K MRCOOL® Hyper Heat Central Ducted Condenser today!

Important

R-454B refrigerant (low GWP). Variable-speed DC inverter. Side-discharge, compact footprint. Smart thermostat included. Pairs with VersaPro® Central Ducted Air Handler (matching capacity).

What's Included

  • Outdoor Condenser (CENTRAL-48-HP-C-230B00-O)
  • MRCOOL® Smart Thermostat
  • Installation & Owner’s Manual
  • Service Manual
  • Warranty Information

Features

  • Up to SEER2 16.5 / EER2 10.5; HSPF4 9.5 / HSPF5 8
  • Eco-forward R-454B refrigerant
  • DC inverter, variable-speed compressor for precise comfort
  • Quiet operation (~65 dBA), compact side-discharge chassis
  • Painted galvanized steel construction
  • Self-diagnostics for easier service
  • Wi-Fi/App control via included Smart Thermostat

Technical Specifications

Brand / Series MRCOOL / Central Ducted Hyper Heat 2nd Gen
Model CENTRAL-48-HP-C-230B00-O
GTIN 00840255586535
UPC 840255586535
Unit Type Split System Heat Pump
Equipment Type Condenser
SEER2 16.5
EER2 10.5
HSPF-4 9.5
HSPF-5 8
CFM (Outdoor Airflow) 3037.1
Tonnage 4
Cooling Capacity (BTU) 48,000
Heating Capacity (BTU) 50,000
Voltage / Phase / Cycle 208–230 V / 1-Phase / 60 Hz
Max Fuse / Breaker (A) 40
Min Circuit Ampacity (A) 38
Color Gray
Refrigerant R-454B
Factory Charge (oz) 134.04
Decibel Rating (dBA) ~65
Liquid / Suction Line Sizes 3/8" / 3/4"
Wi-Fi / App Compatibility Yes / Yes (Smart Thermostat included)
Certifications ETL Certified; AHRI Certified; ENERGY STAR®: Yes
Net Dimensions (W × D × H) 38.58" × 16.34" × 38.39"
Net / Gross Weight 201.06 lbs / 232.36 lbs
Gross Dimensions (W × D × H) 45.08" × 19.68" × 42.52"
Contains Electronics / Chemicals / Compressed Gas Yes / Yes / Yes

Airflow, Refrigerant & Installation Limits

Outdoor Airflow 3037.1 CFM
Line Set Sizes Liquid 3/8" • Suction 3/4"
Line Length & Elevation See Installation/Service Manual for rated & max lengths and elevation limits.
Additional Refrigerant See manual for charge adjustment per added line length.

Compatibility & Pairing

Works With VersaPro® Central Ducted Air Handler (matching capacity)

Warranty Information

  • Base Parts Warranty: 10 Years (limited)
  • Base Compressor Warranty: 10 Years (limited)
  • Base Labor Warranty: 10 Years (limited; automatically activated at installation)

Manuals & Downloads

Safety & Install Notes

  • Install on a solid, level base; follow clearances and anchoring guidance.
  • Dedicated 208/230V, 1-phase circuit; include proper disconnect and follow wiring/torque specifications.
  • Use specified line sizes; evacuate, leak-check, and charge per R-454B (A2L) procedures.
  • Provide adequate ventilation; avoid flammables and corrosive atmospheres near the unit.
  • Comply with national/local codes; installation and service by qualified personnel only.

Environmental & Efficiency Features

Low-GWP R-454B and inverter technology deliver efficient, cold-climate performance with reduced environmental impact and steady comfort.

Specs & Documents Product details Open technical specs, manuals, videos, and product documents.

Technical Data

Specs, manuals, videos, and product documents

Loading technical data…

Product FAQs

Product FAQs

Helpful answers matched to this product, brand, specs, and configuration.
Where should I purchase MRCOOL equipment?

MRCOOL products are sold through authorized retailers and distributors rather than directly by MRCOOL to consumers. Purchasing through an authorized seller helps confirm that the equipment is genuine and that the correct purchase records are available for product and warranty support.

Can MRCOOL components from different series, generations, or refrigerant platforms be mixed?

Do not assume that MRCOOL indoor units, outdoor units, line sets, controls, or accessories are interchangeable. Use only manufacturer-approved combinations for the exact model family; in particular, MRCOOL states that R-410A products are not compatible with R-454B products and the refrigerants must never be mixed.

What makes an eligible MRCOOL DIY system different from a conventional mini-split?

Eligible MRCOOL DIY systems are designed around installation-friendly components such as factory-precharged line sets and compatible connection hardware. The included components vary by generation and package, and electrical work, permits, clearances, and local code requirements still need to be followed.

Does MRCOOL send technicians to a home or jobsite?

MRCOOL does not dispatch field technicians. Its in-house team provides phone and email assistance for diagnosis, troubleshooting, and product guidance, while the owner arranges and pays for any local on-site technician unless a specific written warranty program states otherwise.

Why do I need the exact MRCOOL model and serial number?

The model and serial number identify the exact equipment, generation, capacity, and applicable documentation or warranty. Use the identification labels on the equipment and MRCOOL’s registration guidance rather than relying only on a product title or general series name.

Are all MRCOOL systems designed for do-it-yourself installation?

No. Only product families specifically identified by MRCOOL as DIY-capable should be treated as do-it-yourself systems. Other lines, including the Advantage Series, require professional HVAC installation, so always follow the installation requirements for the exact model.

Where can I find MRCOOL manuals, specifications, certifications, and installation documents?

MRCOOL maintains a documentation library and a product support center with model-specific installation manuals, owner manuals, technical documents, certifications, warranty information, and troubleshooting resources. Search using the exact model number because documents can differ by series, generation, capacity, and refrigerant.

What types of products does MRCOOL offer?

MRCOOL offers a broad range of comfort products, including ductless mini-splits, central ducted split systems, packaged heat pumps, geothermal systems, water heaters, fans, thermostats, line sets, and HVAC accessories. Available capacities, refrigerants, efficiencies, and features depend on the exact product family and model.

When should an MRCOOL system be registered?

Register the system as soon as possible after purchase and installation. Several MRCOOL residential warranty programs require registration within 60 days of installation, or within 60 days of purchase when the installation date cannot be verified, but the exact requirement is controlled by the warranty document for the specific product.

Where can I purchase replacement parts for an MRCOOL system?

MRCOOL recommends starting with the original place of purchase because many dealers can special-order replacement parts. If that is not available, use an authorized MRCOOL parts distributor and confirm compatibility with the exact model and serial number before ordering.

How can I contact MRCOOL customer or technical support?

MRCOOL provides support by phone at (270) 366-0457, by email at support@mrcool.com, and through its online support-request form. Have the exact model and serial number available so the support team can identify the correct product documentation and next steps.

Can MRCOOL support work with my local HVAC technician?

Yes. If a local technician is scheduled, MRCOOL’s in-house support team can help coordinate troubleshooting and product guidance with that technician. The technician should have the model, serial number, system configuration, measurements, error codes, and a clear description of the issue available.

Where can I find MRCOOL troubleshooting and error-code information?

MRCOOL’s support center provides separate technical-support sections for ductless systems, residential ducted systems, product-specific error codes, wiring guidance, installation procedures, and troubleshooting articles. Use the exact series and model because codes and procedures are not universal across all MRCOOL equipment.

How do I register an MRCOOL product for warranty coverage?

Register the product through MRCOOL’s online warranty-registration page. Be prepared to provide the serial number along with purchase, owner, installation-location, and installer information requested by the registration form.

Does every MRCOOL product have the same warranty?

No. MRCOOL publishes separate warranty terms for different product families, generations, and applications. For example, the current DIY 5th Generation warranty lists 5-year parts and 7-year compressor coverage, but that coverage should not be assumed for another MRCOOL series; always check the exact product warranty document.

Customer Reviews Reviews & ratings Open verified customer feedback for this product.