Cooper&Hunter Olivia Series 1 Ton Wall Mount Indoor Unit – 12,000 BTU Ductless Mini Split AC & Heat Pump, R410A, 26.4 SEER, Inverter, 115V, Wi-Fi Enabled – Compatible ONLY with CH-ES12-115VO (Single-Zone)

SKU: CH-12OLVWM-115VI

Brand Cooper&Hunter

Voltage 115v

Refrigerant R410A

AC Type Wall Mount

For Wall Mount

SEER2 Rating 21.7

Free Shipping on Certain Products Above $300

No Sales Tax in Select States

Up to 8% off on bulk orders - call for more details

In stock, ready to ship

Apply for Financing with Breeze

Price

$204.49
Size
save $397.22
save $271.54
save $248.10
save $148.01

NOTE: THE DEFAULT SELECTION DOES NOT INCLUDE AN INSTALLATION KIT. UPGRADE YOUR SELECTION TO ADD TO YOUR ORDER.

Tag Recommended accessories
Loading recommended accessories…
View full details

Cooper&Hunter Olivia Series 12,000 BTU Wall-Mount Indoor Unit – CH-12OLVWM-115VI

A 12,000 BTU wall-mounted indoor unit for a dedicated Cooper&Hunter Olivia single-zone system. Uses R-410A, operates on 115V, includes a handheld remote, and is compatible only with the CH-ES12-115VO outdoor condenser.

Olivia SeriesIndoor Unit Only12,000 BTU115VR-410ASingle Zone 1:1Smart Kit ReadyMatched SEER2 22.7

Why customers choose this indoor unit

  • Horizontal auto-swing: Helps distribute conditioned air evenly across the room.
  • Genius Core technology: Supports ultra-low compressor operation in the matched system for improved modulation and energy performance.
  • 46°F freeze protection: Maintains low-level heating when the space is unoccupied.
  • Smart Kit ready: Optional Wi-Fi control is available through the C&H Remote app.
  • Comfort modes: Includes Turbo, Sleep, Follow Me, timer, Eco, and self-clean functions.
At a glance
Rated capacity
12,000 BTU
Unit type
Wall mount
Power
115V, 1Ph
Compatible condenser
CH-ES12-115VO

What’s included

  • (1) Cooper&Hunter indoor unit: CH-12OLVWM-115VI
  • Manufacturer documentation and available product resources

Indoor component only: The compatible outdoor condenser, refrigerant line set, electrical wiring, drain materials, mounting hardware, and installation accessories are sold separately unless a corresponding product variant specifically includes them.

Control options
  • RG10K handheld remote: Included
  • Smart Kit: Ready for the optional Wi-Fi kit and downloadable C&H Remote app

Compatibility – Single-Zone R-410A Systems

Important: This listing is for the CH-12OLVWM-115VI indoor component only. It is not a complete heating and cooling system and cannot operate without an approved outdoor condenser.

Compatible outdoor condenser

  • CH-ES12-115VO
Correct configuration: One CH-12OLVWM-115VI indoor unit plus one compatible outdoor condenser listed above creates the equipment match. Required piping, electrical, drainage, controls, and installation materials must also be provided.

Key features

  • Horizontal auto-swing: Helps distribute conditioned air evenly across the room.
  • Genius Core technology: Supports ultra-low compressor operation in the matched system for improved modulation and energy performance.
  • 46°F freeze protection: Maintains low-level heating when the space is unoccupied.
  • Smart Kit ready: Optional Wi-Fi control is available through the C&H Remote app.
  • Comfort modes: Includes Turbo, Sleep, Follow Me, timer, Eco, and self-clean functions.
  • User-friendly remote: The included RG10K controller provides direct access to everyday comfort settings.

Technical specifications – CH-12OLVWM-115VI

Model CH-12OLVWM-115VI
Component type Wall-mounted indoor unit only
System configuration Single-zone 1:1 match
Compatible outdoor unit CH-ES12-115VO
Refrigerant R-410A
Rated capacity 12,000 BTU
Power source 115V, 1Ph, 60Hz
Voltage range 103.5-126.5V
Controller RG10K exclusive remote
Matched-system SEER2 22.7
Matched-system EER2 12.5
Dehumidification 2.85 pints per day
Liquid / gas pipe size 1/4 in / 1/2 in
Indoor airflow 341.18 / 300.00 / 241.18 / 176.47 CFM
Indoor noise level, H/M/L 41.5 / 36 / 24 dB(A)
Indoor operating range, heating 32°F to 86°F
Indoor operating range, cooling 60°F to 90°F
Minimum circuit ampacity 3A
Maximum fuse / breaker 15A
Drain connection 5/8 in
Unit dimensions 31.57 x 7.87 x 11.61 in
Packing dimensions 34.45 x 11.22 x 14.96 in
Net / gross weight 18.96 / 24.47 lbs

Performance-rating note: SEER, SEER2, EER, EER2, HSPF, COP, cooling-capacity, and heating-capacity values shown in manufacturer submittals are ratings for a specific approved indoor-and-outdoor equipment match. They are not standalone efficiency ratings for this indoor component.

Product resources

Submittal – CH-ES12-115VO + CH-12OLVWM-115VIOlivia Leaflet 2024Accessories Leaflet 2023Installation ManualOwner’s ManualRemote ManualRemote Manual – Content

Confirm the selected outdoor model, approved match, and installation requirements before purchasing or installing.

Frequently asked questions

Is this a complete mini-split system?
No. This listing is for the CH-12OLVWM-115VI indoor wall unit only.

Which outdoor unit is compatible?
This indoor unit is compatible only with the CH-ES12-115VO single-zone outdoor condenser.

Does the indoor unit itself have a 22.7 SEER2 rating?
No. The 22.7 SEER2 value applies to the approved indoor-and-outdoor match shown in the submittal.

Is Wi-Fi included?
The unit is Smart Kit ready. Wi-Fi control requires the optional Cooper&Hunter Smart Kit and the C&H Remote app.

Is a remote included?
Yes. The supplied specifications list an RG10K handheld remote.

Product specifications, approved combinations, documentation, and warranty terms may be revised by the manufacturer. Verify compatibility and current technical requirements before installation.


Loading accessories…

We will prepare your order within 24 hours if it’s received on a weekday (before noon). Orders are shipped in one to two business days. Transit time is between 3 to 6 business days, although exceptions apply. We email tracking information once your purchase is shipped.

Delivery Map

IMPORTANT DELIVERY INFORMATION: Please be kindly informed that this air conditioner, due to its weight and shipping restrictions, is shipped palletized with an arranged freight service and requires an appointment for delivery. To AVOID delays, please check if the provided phone number in the order details is a current number where you can be reached. You can also contact the carrier directly and refer to your tracking number to set up a date and time for your appointment. It is your responsibility to ensure a safe and secure environment for delivery. Please note that we cannot be held liable for any packages that are stolen or lost after delivery has been confirmed. PLEASE verify your shipping address, as changes to the address after freight has shipped can result in an additional 15% or higher fee depending on freight weight and dimensions.

SMALLWARES INFORMATION: Please be informed that for smaller items, such as Installation Kits, Smart Connectivity Dongles, and TTW Sleeves, when these items are ordered individually, they may be shipped via FedEx without a signature requirement. It is your responsibility to ensure a safe and secure environment for delivery. Please note that we cannot be held liable for any packages that are stolen or lost after delivery has been confirmed. Thank you for your understanding and cooperation.

INSPECT YOUR MERCHANDISE BEFORE SIGNING: Please inspect your boxes thoroughly when you receive them. They should arrive shrink-wrapped and on a pallet. If you notice any damages or imperfections (e.g. crushed box or forklift hole), please write comments on the receipt before signing for delivery, no matter how small damages seem. Contact us immediately to assist you.

Shipping & Delivery

We will prepare your order within 24–48 hours if it’s received on a weekday (before noon). Orders are shipped in one to two business days. Transit time is between 3 to 6 business days, although exceptions apply. We email tracking information once your purchase is shipped.

Delivery Map

Shipping Times Map

IMPORTANT DELIVERY INFORMATION

Please be informed that this air conditioner, due to its weight and shipping restrictions, is shipped palletized with an arranged freight service and requires an appointment for delivery.

To AVOID delays, please make sure the phone number in your order details is accurate and one where you can be reached. You may also contact the carrier directly using your tracking number to schedule your delivery.

It is your responsibility to ensure a safe and secure delivery environment. We are not liable for any packages that are stolen or lost after delivery is confirmed.

Please verify your shipping address carefully. Changes to your shipping address after the freight has been shipped may result in additional fees of 15% or more, depending on freight weight and dimensions.


SMALLWARES INFORMATION

Smaller items such as Installation Kits, Smart Connectivity Dongles, and TTW Sleeves may be shipped via FedEx without a signature requirement if ordered individually.

It is your responsibility to ensure a safe delivery location. We are not liable for packages lost or stolen after delivery confirmation. Thank you for your understanding and cooperation.


INSPECT YOUR MERCHANDISE BEFORE SIGNING

Please inspect your boxes carefully upon delivery. Shipments should arrive shrink-wrapped and on a pallet. If you notice any damage or signs of mishandling (such as a crushed box or forklift puncture), write comments on the delivery receipt before signing, even if the damage appears minor.

Contact us immediately if any issues arise so we can assist you promptly.


SMS Delivery Notifications

If you opted into SMS notifications, we may send you order updates or delivery reminders by text message. Message frequency may vary. Message and data rates may apply. Text STOP to opt out. Text HELP for assistance.

For more details, see our Privacy Policy.

Loading technical data…