Technical Data
Specs, manuals, videos, and product documents
Loading technical data…
Volume rewards
Example: a $10,000 BRAVO order saves $1,000 automatically.
| Qualifying subtotal | $5K | $10K | $15K | $50K |
|---|---|---|---|---|
| BRAVO | 5% | 10% | 13% | 15% |
| Other eligible brands | 3% | 5% | 6% | 8% |
The highest eligible tier is applied automatically to qualifying regularly priced merchandise.
Important: Bulk discounts cannot be combined with products that already have a current discount, sale price, or other promotional offer.
Click image to zoom
A smart, reliable choice for year-round comfort.
Recommended Add-Ons
Loading recommended accessories…
CLICK TO CALL US 737-738-6329 FOR ANY QUESTIONS
The Cooper & Hunter MIA NY Series Mini Split Air Conditioner is a versatile, energy-efficient, and affordable ductless AC unit, designed to provide year-round comfort for homes, offices, and bedrooms. Available in 6,000, 9,000, 12,000, 18,000, and 24,000 BTU, this system is ideal for small to large spaces, ensuring quiet, efficient cooling and heating with its up to 22 SEER inverter technology.
This mini split AC unit is engineered for superior energy savings, offering precise temperature control while maintaining low power consumption. It operates efficiently in temperatures as low as 5°F, making it a reliable heating and cooling solution in all seasons.
With its sleek design, smart technology, and energy-efficient performance, the Cooper & Hunter MIA Series Mini Split AC is the perfect ductless HVAC solution for those seeking affordable, high-performance cooling and heating.
Important: With its high-efficiency SEER rating, the Cooper & Hunter MIA Series ensures year-round energy savings. This model includes a Toshiba-GMCC inverter compressor, protected by a 7-year warranty on the compressor and 5 years on parts. Warranty registration must be completed within 60 days of installation.
Cooper & Hunter Single Zone Ductless Mini Split System (18,000 BTU Inverter with Heat Pump)
Outdoor Unit: 18,000 BTU (1pc) – Model: CH-RLS18MIA-230VO
Indoor Unit: 18,000 BTU (1pc with remote) – Model: CH-RLS18MIA-230VI
Wi-Fi Adapter
16ft Installation Kit
All units must be installed by a licensed HVAC professional for the warranty to be valid. Registration is required within 60 days of installation and can be completed online or by phone. The installation kit is necessary for the system to function. Ensure that you have selected the desired installation kit above. This kit comes with Pre-Flared 99% Copper Lines, Data Communication Wires, PVC Drainage Attachment, Wrapping Bands, etc.
| Capacity | Standard Models (Mia Series) | Voltage | Refrigerant |
|---|---|---|---|
| 6,000 BTU | CH-RLS06MIA-115VI + CH-RLS06MIA-115VO | 115V | R454B |
| 9,000 BTU | CH-RLS09MIA-115VI + CH-RLS09MIA-115VO | 115V | R454B |
| 12,000 BTU | CH-RLS12MIA-115VI + CH-RLS12MIA-115VO | 115V | R454B |
| 9,000 BTU | CH-RLS09MIA-230VI + CH-RLS09MIA-230VO | 230V | R454B |
| 12,000 BTU | CH-RLS12MIA-230VI + CH-RLS12MIA-230VO | 230V | R454B |
| 18,000 BTU | CH-RLS18MIA-230VI + CH-RLS18MIA-230VO | 230V | R454B |
| 24,000 BTU | CH-RLS24MIA-230VI + CH-RLS24MIA-230VO | 230V | R454B |
| Power Supply | Rated | V, Ph, Hz | 208/230,1 |
|
Rated Capacity
|
Heated | 18,000 | |
| Cooling | Btu/h | 18,800 | |
| Minimum Circuit Ampacity (MCA) | A | 3 | |
| Max. Fuse | A | 15 | |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | CFM | 429.7/388.5/259.0/ 217.8// | |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | CFM | 40.5/35.5/31.5/ 23.0/18.5 | |
|
Indoor
|
Dimensions | inch | 37.99x8.46x12.56 |
| Packing | inch | 41.14x12.01x16.14 | |
| Net/Gross Weight | lbs. | 24.47/32.63 | |
|
Room temperature
|
Cooling | °F | 60-90 |
| Heating | °F | 32-86 | |
| Liquid Side/Gas Side | Inch | 1/4"/1/2" | |
|
Power Supply
|
Rated | V, Ph, Hz | 208/230,1,60 |
| Voltage Range | V | 187-253 | |
|
Cooling
|
Rated Capacity (Range) | Btu/h | 4,100-19,000 |
| Rated Current | A | 7.2 | |
| EER2 | Btu/h | 10.8 | |
| SEER2 | Btu/h | 19.2 | |
|
Heating at 47°F
|
Rated Capacity (Range) | Btu/h | 6,200-20,200 |
| Rated Current | A | 8.1 | |
| COP | W/W | 3.06 | |
| HSPF4 | 9.6 | ||
| HSPF5 | 7.5 | ||
| Minimum Circuit Ampacity | A | 15 | |
| Max. Fuse (Outdoor Unit) | A | 20 | |
| Outdoor Air Flow (Max.) | CFM | 1,235.30 | |
| Outdoor Noise Level (Sound Pressure) | dB(A) | 56 | |
| Dimension (W×D×H) | inch | 31.88x12.99x21.81 | |
| Packing (W×D×H) | inch | 37.0x16.14x23.81 | |
| Net/Gross Weight | lbs. | 72.31/78.48 | |
| Refrigerant Type / Charge | oz. | R454B/40.57 | |
| Refrigerant Precharge Length | ft. | 25 | |
| Additional Charge for Each ft. | oz/ft | 0.16 | |
| Design Pressure | PSIG | 550/340 | |
| Refrigerant Piping Liquid Side/Gas Side | inch | 1/4"/1/2" | |
| Max. Pipe Length | ft. | 98.4 | |
| Max. Difference in Level | ft. | 65.6 | |
|
Ambient Temperature
|
Cooling | °F | 5-122 |
| Heating | °F | 5-75 | |
|
Certifications
|
ETL | TRUE | |
| AHRI | TRUE | ||
| Energy Star for Cold Climate | TRUE | ||
| NEEP | TRUE | ||

Technical Data
Loading technical data…
Product FAQs
On compatible systems, the app can provide remote on and off control, temperature adjustment, operating-mode selection, fan-speed control, daily or weekly scheduling, customized sleep settings, and an error-code check function. Available features can vary by model and app version.
Yes. Cooper & Hunter states that multiple users can connect and share control of compatible zones or units through the Cooper & Hunter Remote app, which can be useful for households, offices, and multi-zone installations.
Use the exact model number from the equipment label to search Cooper & Hunter’s website or support center. Confirm that the indoor unit, outdoor unit, voltage, capacity, and series shown in the result match the equipment before relying on the manual, submittal, leaflet, or troubleshooting material.
Yes. Cooper & Hunter’s support center allows installers to sign in or register for a personal account to access troubleshooting resources. Warranty diagnosis may still require direct troubleshooting with a Cooper & Hunter Technical Support agent while the technician is on site.
Yes. Cooper & Hunter’s Limited Warranty states that qualifying equipment must be properly installed by a state-certified or licensed HVAC contractor in accordance with applicable codes, permits, manufacturer instructions, and accepted trade practices.
Cooper & Hunter provides product manuals, troubleshooting guides, warranty information, product-specific documents, and selected troubleshooting videos through its official support center. Search using the exact model number to avoid using instructions for a different system.
Yes. Cooper & Hunter’s official website includes a Find Solution tool for selecting a system by application and climate zone, along with a dealer locator. Final equipment selection should still be confirmed against the project load, electrical requirements, installation conditions, and the exact product documentation.
Use Cooper & Hunter’s official Rebates & Incentives portal and enter the requested location and equipment information. Eligibility depends on the exact model, efficiency requirements, installation details, utility program, tax rules, and customer location.
No. Cooper & Hunter states that its systems meet guidelines in many regions and may qualify for rebates or other incentives, but availability and approval depend on the local program and the exact equipment. Verify eligibility before treating an incentive as part of the final project cost.
Compatible systems use the Cooper & Hunter Remote app, available through the Apple App Store and Google Play. The exact system must support Wi-Fi control and may require the manufacturer’s compatible wireless module or smart kit.
No. Cooper & Hunter’s Smart Kit instructions state that the reserved interface is intended for the manufacturer-provided compatible wireless module. Power should be disconnected before installation, and access, replacement, and maintenance of the wireless module should be handled by qualified personnel.
For the eligible product categories listed on its warranty page, Cooper & Hunter publishes one year of coverage for the original remote control, five years on parts, and seven years on the compressor for the original registered end user. Exact coverage can vary by product, purchase channel, registration status, and program eligibility, so confirm the warranty for the exact model.
The product owner or servicing technician should contact Cooper & Hunter Technical Support. For warranty troubleshooting, Cooper & Hunter instructs that the technician should be on site so the support agent can review error codes, symptoms, electrical readings, mechanical measurements, and other diagnostic information.
Have the unit model and serial number, installation date, installer’s EPA or HVAC license information, and the place of purchase available. Cooper & Hunter may also request photographs, error codes, measurements, or other diagnostic details before processing warranty support.
Yes. Cooper & Hunter’s support center states that one-on-one technical and warranty assistance is available in English, Spanish, Mandarin, Russian, and Ukrainian.
Cooper & Hunter lists Technical Support at (888) 293-9252 and an additional number at (786) 953-6706. Its support center currently lists availability Monday through Friday from 9:00 AM to 8:00 PM Eastern Time. Check the official support page for current hours before calling.
Cooper & Hunter’s published policy excludes labor and related field costs. It also states that refrigerant, charging, recharging, adjustment, and removal costs are not covered. The owner is generally responsible for these expenses even when an eligible replacement part is provided.
Register the equipment through Cooper & Hunter’s official warranty registration process. Registration can be completed online or by phone. Keep the model and serial numbers for each piece of equipment, the installation and purchase details, and the installing contractor’s information available before starting.
Cooper & Hunter states that products should be registered within 60 days of installation for its Limited Warranty. Registration and coverage remain subject to the current warranty policy and the eligibility requirements for the specific product.
Cooper & Hunter requests the model and serial number for each piece of equipment, installation date, owner contact information, installer or dealer information, purchase details, an email address, and the HVAC license number. Much of this information should be available on the product labels and installation invoice.
Yes. Cooper & Hunter’s published policy states that warranty coverage applies to products remaining at their original installation location. Equipment removed and reinstalled elsewhere may be excluded from warranty coverage.
Yes. Cooper & Hunter lists damage or repairs arising from non-compatible parts, third-party components, alterations, modifications, or improper applications among its warranty exclusions. Use components approved for the exact equipment and application.
Cooper & Hunter’s published Limited Warranty is provided to the first original owner at the original installation location and is not transferable to subsequent owners. Review the current warranty policy for the exact product and transaction.
No. Wi-Fi and app compatibility are model dependent. Some systems include compatible wireless capability, while others require a specific Cooper & Hunter Wi-Fi accessory or do not support app control. Confirm the exact model’s product documents and accessory compatibility before ordering.
Active Clean freezes and then rapidly thaws the indoor heat exchanger so condensed water can help wash away accumulated dust, mold, and grease. The indoor fan then uses warm air to dry the evaporator. The indoor display shows CL while the cycle is running, and the cycle normally ends automatically after about 20 to 45 minutes.
Yes. The MIA manual lists an Auto-Restart function that restores operation using the prior settings after power is restored.
Breeze Away changes the airflow pattern to reduce direct air blowing on occupants. The remote-controller manual lists this function for COOL, FAN, and DRY modes. Feature availability can vary by exact model, so confirm that the Breeze Away symbol or button is supported by the unit.
The manual lists 6,000 BTU MIA models in 115V; 9,000 BTU models in 115V or 230V; 12,000 BTU models in 115V or 230V; and 18,000 and 24,000 BTU models in 230V. Confirm the exact voltage and model number before ordering or installation.
CL indicates that Active Clean is running, dF indicates a defrost cycle, and FP indicates the 46°F (8°C) heat-maintenance function. The display can also show the temperature, operating-feature indicators, wireless-control status, timer status, and error codes.
ECO and GEAR are available in COOL mode. ECO uses an automatic fan setting and, when the setpoint is below 75°F (24°C), adjusts it to 75°F to reduce energy use. GEAR cycles through approximately 75% and 50% electrical-consumption limits before returning to the previous setting. Reduced-energy modes can also reduce cooling output.
FHCC indicates a refrigerant-sensor malfunction on models equipped with that sensor. The manual lists a 15-year sensor service life and states that the sensor is not repairable; it must be replaced with the manufacturer-specified sensor by qualified service personnel.
Follow Me uses the temperature sensor in the remote controller instead of relying only on the indoor-unit sensor. In AUTO, COOL, or HEAT mode, the remote sends its measured temperature to the unit about every three minutes so the system can regulate comfort closer to the remote location. A memory option can keep Follow Me active through certain mode changes or power interruptions.
FP is a low-temperature heat-maintenance function for heat-pump models. The remote manual describes activating it while the unit is in HEAT mode with the setpoint at 60°F (16°C). The system then operates at high fan speed while the compressor is running and targets approximately 46°F (8°C).
The manual lists the mounting plate and cardboard template, drain joint, seal, anchors, mounting-plate screws, two copper nuts, remote controller, two batteries, and one or two small filters among the supplied items. The remote-controller holder and its screws, refrigerant piping, connection cable, and outdoor-unit power cable are shown as separate or model-dependent items. Always compare the carton contents with the exact model packing list.
The documented pairs are: 6K 115V - CH-RLS06MIA-115VI with CH-RLS06MIA-115VO; 9K 115V - CH-RLS09MIA-115VI with CH-RLS09MIA-115VO; 9K 230V - CH-RLS09MIA-230VI with CH-RLS09MIA-230VO; 12K 115V - CH-RLS12MIA-115VI with CH-RLS12MIA-115VO; 12K 230V - CH-RLS12MIA-230VI with CH-RLS12MIA-230VO; 18K 230V - CH-RLS18MIA-230VI with CH-RLS18MIA-230VO; and 24K 230V - CH-RLS24MIA-230VI with CH-RLS24MIA-230VO.
The installation summary shows at least 5.9 inches (15 cm) above the indoor unit, more than 4.72 inches (12 cm) on each side, and at least 70.87 inches (1.8 m) from the floor. The wall hole is generally 2.5 inches (65 mm) when the gas line is smaller than 5/8 inch, or 3.54 inches (90 mm) when the gas line is 5/8 inch or larger. The hole should slope downward toward the outdoors by approximately 0.2 to 0.275 inch (5 to 7 mm).
The manual requires a minimum piping run of 9.84 feet (3 m) and notes that nominal efficiency is tested with 25 feet (7.5 m) of piping. Maximum listed lengths and vertical drops are: 9K/12K - 82 feet maximum with 49.2 feet maximum drop; 18K - 98.4 feet with 65.6 feet drop; and 24K - 164 feet with 82 feet drop. Final design should follow the exact model submittal and installation requirements.
The MIA installation table lists 9K and 12K models with a 1/4-inch liquid line and 3/8-inch gas line; 18K with a 1/4-inch liquid line and 1/2-inch gas line; and 24K with a 3/8-inch liquid line and 5/8-inch gas line. The table does not clearly list the 6K piping size, so use the model submittal or unit labeling for that size.
Yes. The MIA manual lists Louver Angle Memory, which returns the louver to its previous angle when the unit is turned on again.
Yes, for emergency or testing use. With the unit off, open the indoor front panel and locate the Manual Control button on the right side. Press once for Forced Auto, press again for Forced Cooling, and press a third time to turn the unit off. Regular operation should be restored with the remote controller.
The MIA manual describes an outdoor heat-exchanger dust-removal function. After the unit is turned off, there is approximately a 10-second delay and the outdoor fan runs in reverse for about 70 seconds to blow away loose dust and debris. This feature can help keep the coil cleaner, but it does not replace normal inspection and maintenance.
The MIA manual states that a buzzing sound is heard each time the air conditioner is powered on to confirm normal power-up. If no sound is heard, the manual recommends powering the unit on again or checking the electrical circuit.
The MIA Series models covered by this manual use R454B refrigerant. R454B is identified as an A2L flammable refrigerant, so installation, leak testing, charging, recovery, and service should be performed by qualified personnel using procedures and equipment suitable for R454B.
Yes. The manual states that the bottom of the indoor unit should be at least 6.0 feet (1.8 m) above the floor and the room height should not be less than 7.3 feet (2.2 m). The required minimum room area depends on the system refrigerant charge and installation height, so the model-specific table and installation documentation must be checked before installation.
On MIA units equipped with a refrigerant sensor, a detected leak causes the indoor unit to show an error code and sound a buzzer. The outdoor compressor stops immediately and the indoor fan starts running. The manual states that the unit should remain powered except while it is being serviced so the detection system can operate.
The remote controller is designed to support several related unit configurations, so some buttons or icons may not apply to every MIA model. If the indoor unit does not support a function, pressing that button has no effect. When the remote manual and the unit owner manual differ, follow the MIA owner manual for the installed model.
In COOL mode, Sleep raises the set temperature by 2°F (1°C) after the first hour and another 2°F (1°C) after the second hour. In HEAT mode, it lowers the set temperature by the same amount during each of the first two hours. The Sleep adjustment ends after eight hours and the system continues at the final setting. Sleep is not available in FAN or DRY mode.
In HEAT or AUTO-heating mode, holding the Turbo button for more than five seconds activates Super Heat. The louver opens to its maximum angle and the system prioritizes faster heating, especially in low outdoor temperatures. Hold Turbo for more than three seconds to stop it. The manual notes that discharge air may initially feel cooler because the anti-cold-air feature is temporarily disabled.
The MIA documentation lists wireless control for app-control units and identifies a Smart Kit on the manual cover. To begin network configuration, select AP mode through the remote SET menu. If AP mode does not start through SET, the remote manual instructs pressing the LED button seven times within 10 seconds. Wireless availability should be confirmed for the exact MIA model.