SKU CH-NHPR48LCU-230VO Outdoor Unit
$2,822.85
Currently unavailableContact us for lead time
High efficiency. Quiet performance. Easy installation.

A smart, reliable choice for year-round comfort.

Best for:
  • Bedrooms
  • Home Offices
  • Additions
  • Garages
See specs
Cooling
See specs
Heating
See specs
Quiet Inside
See specs
High Efficiency

Brand Information

Cooper&Hunter
Support Number
1 888-293-9252
Product Overview Full product description Read the longer product copy, features, and application notes.

Cooper&Hunter Light Commercial Hyper Heat 48,000 BTU Single-Zone Outdoor Condenser (R-410A) – CH-HYP48LCUO

A powerful one-to-one light commercial solution for larger spaces—businesses, warehouses, workshops, and grow rooms—with cold-climate heating down to -22°F. Pairs with compatible 48K indoor unit styles: Ceiling Cassette, Universal Floor/Ceiling, Slim Duct, and Air Handler.

Light Commercial Hyper 48,000 BTU Single Zone (1:1) R-410A Refrigerant Heats to -22°F SEER 16.5 Max line length 213 ft 208–230V Class

Why this is the right fit for larger spaces

  • Built for demanding loads: 48K capacity for big open areas and light commercial applications.
  • Cold-climate performance: operates in heating down to -22°F.
  • Flexible indoor styles: pair one-to-one with cassette, floor/ceiling, slim duct, or air handler (see compatibility list below).
  • Long line-set capability: up to 213 ft total line length and up to 98 ft elevation difference (verify install design).
  • R-410A system: designed for R-410A matched components.
At-a-glance
Cooling
48,000 BTU (rated)
Heating
50,000 BTU (rated)
Efficiency
SEER 16.5
Refrigerant
R-410A (148 oz)

 

What’s included

  • (1) Outdoor condenser: CH-HYP48LCUO
  • Manufacturer documentation (manuals/spec sheets as applicable)

Outdoor unit only: indoor unit, line set, and installation materials are sold separately unless your bundle selection includes them.

Electrical (outdoor)
  • MCA: 36.3A
  • Max fuse/breaker: 50A
  • Rated current (cooling / heating): 24.22A / 19.30A

Compatibility (Single-Zone / R-410A only)

Important: This condenser supports ONE (1) indoor unit maximum. It is not a multi-zone condenser. Use R-410A compatible 48K indoor models listed below.

Compatible R-410A indoor units (48K Light Commercial)

Universal Floor/Ceiling

  • 48K Universal Floor/Ceiling Indoor: CH-48LCFC/I (panel: CJ-48LCFC-W)

Four-Way Ceiling Cassette

  • 48K Ceiling Cassette: CH-N48LCCT-230VI (panel: CH-48LCCT-W)

Slim Duct

  • 48K Slim Duct: CH-48LCDTU/I

Air Handler (AHU)

  • 48K Air Handler: CH-48AHU
Direct replacement note: CH-HYP48LCUO can replace CH-NHPR48LCU-230VO (Hyper) and CH-N48LCU-230VO (Standard) outdoor condensers in single-zone R-410A light commercial applications.

Key features

  • Light commercial power: designed for larger spaces and higher demand environments
  • Cold climate heating: operation down to -22°F (ambient)
  • Indoor style flexibility: supports cassette, floor/ceiling, slim duct, and air handler configurations (1:1 only)
  • Long piping capability: up to 213 ft line length; up to 98 ft elevation difference
  • Durable rotary compressor with high airflow and robust performance

Tech specs (Outdoor Condenser: CH-HYP48LCUO)

Cooling capacity (rated) 48,000 BTU/h
Heating capacity (rated) 50,000 BTU/h
SEER 16.5
EER 8.3
HSPF4 / HSPF5 @ 47°F 10.7 / 9.2
COP @ 47°F 2.93
Refrigerant R-410A (factory charge 148 oz; pre-charge length 25 ft)
Operating temp (heating) -22°F to 86°F
Operating temp (cooling) -22°F to 122°F
Outdoor air flow 4,470 CFM
Outdoor noise level 65 dB(A)
Max line length 213 ft
Max height difference 98 ft
MCA 36.3A
Max fuse/breaker 50A
Dimensions (W×H×D) 37.5 × 16.3 × 52.5 in
Net / Gross weight 227.1 / 255.7 lbs
Design pressure 550/340 PSIG
Additional refrigerant (3/8" liquid) 0.32 (per ft, per manufacturer guidance)

If your installed line length exceeds the factory pre-charge piping length (25 ft), additional refrigerant may be required per manufacturer procedure.

AHRI reference (as provided): 205282615.

FAQs

Is this a complete system?
No. This listing is for the outdoor condenser only. You must pair it with one compatible 48K R-410A indoor unit (see compatibility list above).

Can I connect multiple indoor units?
No. This is a single-zone condenser (max 1 indoor unit).

Can it replace CH-NHPR48LCU-230VO or CH-N48LCU-230VO?
Yes—this is a replacement option for those outdoor condensers in single-zone R-410A applications.

What indoor unit styles are supported?
One-to-one pairing with compatible Ceiling Cassette, Universal Floor/Ceiling, Slim Duct, or Air Handler indoor units.

Specs & Documents Product details Open technical specs, manuals, videos, and product documents.

Technical Data

Specs, manuals, videos, and product documents

Loading technical data…

Product FAQs

Product FAQs

Helpful answers matched to this product, brand, specs, and configuration.
What can the Cooper & Hunter Remote app control?

On compatible systems, the app can provide remote on and off control, temperature adjustment, operating-mode selection, fan-speed control, daily or weekly scheduling, customized sleep settings, and an error-code check function. Available features can vary by model and app version.

Can multiple people control compatible Cooper & Hunter systems through the app?

Yes. Cooper & Hunter states that multiple users can connect and share control of compatible zones or units through the Cooper & Hunter Remote app, which can be useful for households, offices, and multi-zone installations.

How do I find the correct Cooper & Hunter manual or submittal for my unit?

Use the exact model number from the equipment label to search Cooper & Hunter’s website or support center. Confirm that the indoor unit, outdoor unit, voltage, capacity, and series shown in the result match the equipment before relying on the manual, submittal, leaflet, or troubleshooting material.

Does Cooper & Hunter provide dedicated troubleshooting resources for installers?

Yes. Cooper & Hunter’s support center allows installers to sign in or register for a personal account to access troubleshooting resources. Warranty diagnosis may still require direct troubleshooting with a Cooper & Hunter Technical Support agent while the technician is on site.

Does Cooper & Hunter require licensed HVAC installation for warranty coverage?

Yes. Cooper & Hunter’s Limited Warranty states that qualifying equipment must be properly installed by a state-certified or licensed HVAC contractor in accordance with applicable codes, permits, manufacturer instructions, and accepted trade practices.

What Cooper & Hunter support resources are available online?

Cooper & Hunter provides product manuals, troubleshooting guides, warranty information, product-specific documents, and selected troubleshooting videos through its official support center. Search using the exact model number to avoid using instructions for a different system.

Does Cooper & Hunter provide a product-selection or dealer-locator tool?

Yes. Cooper & Hunter’s official website includes a Find Solution tool for selecting a system by application and climate zone, along with a dealer locator. Final equipment selection should still be confirmed against the project load, electrical requirements, installation conditions, and the exact product documentation.

How can I check whether a Cooper & Hunter system qualifies for rebates or incentives?

Use Cooper & Hunter’s official Rebates & Incentives portal and enter the requested location and equipment information. Eligibility depends on the exact model, efficiency requirements, installation details, utility program, tax rules, and customer location.

Is a rebate guaranteed when purchasing a Cooper & Hunter system?

No. Cooper & Hunter states that its systems meet guidelines in many regions and may qualify for rebates or other incentives, but availability and approval depend on the local program and the exact equipment. Verify eligibility before treating an incentive as part of the final project cost.

Which mobile app is used with compatible Cooper & Hunter systems?

Compatible systems use the Cooper & Hunter Remote app, available through the Apple App Store and Google Play. The exact system must support Wi-Fi control and may require the manufacturer’s compatible wireless module or smart kit.

Can any wireless adapter be used with a Cooper & Hunter system?

No. Cooper & Hunter’s Smart Kit instructions state that the reserved interface is intended for the manufacturer-provided compatible wireless module. Power should be disconnected before installation, and access, replacement, and maintenance of the wireless module should be handled by qualified personnel.

What standard warranty periods does Cooper & Hunter publish?

For the eligible product categories listed on its warranty page, Cooper & Hunter publishes one year of coverage for the original remote control, five years on parts, and seven years on the compressor for the original registered end user. Exact coverage can vary by product, purchase channel, registration status, and program eligibility, so confirm the warranty for the exact model.

How is a Cooper & Hunter warranty claim started?

The product owner or servicing technician should contact Cooper & Hunter Technical Support. For warranty troubleshooting, Cooper & Hunter instructs that the technician should be on site so the support agent can review error codes, symptoms, electrical readings, mechanical measurements, and other diagnostic information.

What information should be ready when contacting Cooper & Hunter Technical Support?

Have the unit model and serial number, installation date, installer’s EPA or HVAC license information, and the place of purchase available. Cooper & Hunter may also request photographs, error codes, measurements, or other diagnostic details before processing warranty support.

Does Cooper & Hunter offer technical support in multiple languages?

Yes. Cooper & Hunter’s support center states that one-on-one technical and warranty assistance is available in English, Spanish, Mandarin, Russian, and Ukrainian.

How can I contact Cooper & Hunter Technical Support?

Cooper & Hunter lists Technical Support at (888) 293-9252 and an additional number at (786) 953-6706. Its support center currently lists availability Monday through Friday from 9:00 AM to 8:00 PM Eastern Time. Check the official support page for current hours before calling.

Does Cooper & Hunter’s warranty cover labor or refrigerant costs?

Cooper & Hunter’s published policy excludes labor and related field costs. It also states that refrigerant, charging, recharging, adjustment, and removal costs are not covered. The owner is generally responsible for these expenses even when an eligible replacement part is provided.

How do I register my Cooper & Hunter product warranty?

Register the equipment through Cooper & Hunter’s official warranty registration process. Registration can be completed online or by phone. Keep the model and serial numbers for each piece of equipment, the installation and purchase details, and the installing contractor’s information available before starting.

How soon should a Cooper & Hunter system be registered for warranty?

Cooper & Hunter states that products should be registered within 60 days of installation for its Limited Warranty. Registration and coverage remain subject to the current warranty policy and the eligibility requirements for the specific product.

What information is needed to register a Cooper & Hunter system?

Cooper & Hunter requests the model and serial number for each piece of equipment, installation date, owner contact information, installer or dealer information, purchase details, an email address, and the HVAC license number. Much of this information should be available on the product labels and installation invoice.

Can moving a Cooper & Hunter system affect its warranty?

Yes. Cooper & Hunter’s published policy states that warranty coverage applies to products remaining at their original installation location. Equipment removed and reinstalled elsewhere may be excluded from warranty coverage.

Can non-compatible or third-party components affect Cooper & Hunter warranty coverage?

Yes. Cooper & Hunter lists damage or repairs arising from non-compatible parts, third-party components, alterations, modifications, or improper applications among its warranty exclusions. Use components approved for the exact equipment and application.

Is a Cooper & Hunter Limited Warranty transferable to a new owner?

Cooper & Hunter’s published Limited Warranty is provided to the first original owner at the original installation location and is not transferable to subsequent owners. Review the current warranty policy for the exact product and transaction.

Are all Cooper & Hunter systems compatible with the Cooper & Hunter Remote app?

No. Wi-Fi and app compatibility are model dependent. Some systems include compatible wireless capability, while others require a specific Cooper & Hunter Wi-Fi accessory or do not support app control. Confirm the exact model’s product documents and accessory compatibility before ordering.