Cooper & Hunter Slim Duct Hyper 12,000 BTU 230V R454B Concealed Duct Air Conditioning Unit for Heat Pump Mini Split Inverter System 21.4 SEER2 1 TON With Wi-Fi Enabled Thermostat & Optional Installation Kit CH-RS12MDT-MS + CH-RHP12-230V0
Vendor:Cooper&HunterRegular price $1,856.00Sale price $1,856.00 Regular priceUnit price per -
Sold out3 Zone 9k+9k+9k Concealed Duct with Installation Kits, 21 SEER2 2.3 Ton Tri Zone Slim Duct Air Conditioners
Vendor:Cooper & HunterRegular price $3,901.00Sale price $3,901.00 Regular priceUnit price perSold out -
Sold out36,000 BTU 4 Zone 9k+9k+9k+9k Concealed Duct Mini Split with 25ft Installation Kits, 20 SEER2 3 Ton Quad Zone Slim Duct AC System
Vendor:Cooper & HunterRegular price $5,600.00Sale price $5,600.00 Regular priceUnit price perSold out -
Sold out48,000 BTU 5 Zone 9k+9k+9k+12k+12k Ductless Mini Split with Installation Kits, Olivia Series 22.4 SEER 4 Ton Penta Zone Five Zone Air Conditioner System
Vendor:Cooper&HunterRegular price $5,976.00Sale price $5,976.00 Regular priceUnit price per$5,364.00Sold out -
Sold out48,000 BTU 5 Zone 9k+9k+9k+9k+9k Concealed Duct Mini Split with Installation Kits, 20.5 SEER2 4 Ton Penta Zone Five Zone Slim Duct Air Conditioners
Vendor:Cooper&HunterRegular price $6,803.94Sale price $6,803.94 Regular priceUnit price perSold out
wishlist
Welcome to the South Mini Splits collection for Ducted System. We feature high-efficiency systems from industry leaders like Cooper & Hunter, OLMO, MRCOOL, and Bravo.
These systems provide whole-home comfort through discreet installation, connecting to traditional ductwork while maintaining the superior efficiency of mini-split technology.
💡Why Choose South Mini Splits for Your Ducted System?
✅ Wholesale Pricing: Competitive rates on top-tier HVAC equipment.
✅ USA-Based Support: Expert help from sizing to post-install troubleshooting.
✅ Free Shipping Over $300: Get your complete system delivered fast.
What is a Ducted Mini Split System?
A Ducted Mini Split System uses a central indoor air handler or concealed duct unit to distribute conditioned air through a network of existing or new ductwork, providing uniform climate control across multiple rooms or an entire floor.
Ducted Applications & Advantages
Ducted mini splits are the ideal solution when maintaining aesthetics and whole-home consistency is a priority:
- Whole-Home Replacement: They offer a high-efficiency alternative to traditional central AC and heat pumps, connecting seamlessly to the home’s existing ductwork and vents.
- Remodeling & New Construction: Concealed Ducted Units are installed in attics, ceilings, or crawl spaces, hiding the indoor unit entirely while providing temperature consistency across all rooms connected to the air distribution system.
- Zoning Control (Multi-Zone Integration): A Ducted Air Handler can function as one zone in a larger multi-zone system, allowing for independent temperature control over a large area (like a living room and hallway) while other zones use wall mounts or ceiling cassettes.
- Noise Reduction: Since the unit is concealed outside the living space (in a closet, ceiling, or attic), ducted units offer the quietest operational experience.
Technical Insight: The Importance of Static Pressure
For customers installing or replacing a ducted unit, understanding static pressure is crucial for system performance:
- What is Static Pressure? Static pressure measures the resistance to airflow caused by duct friction, filters, and dampers. High static pressure forces the blower to work harder, decreasing airflow and efficiency.
- Ducted System Design: Modern mini-split air handlers are designed to handle higher external static pressure than many residential units, offering greater flexibility in duct design.
Avoiding Short Cycling: Just like other mini-splits, the Ducted Air Handler must be correctly sized (BTU capacity) for the area it serves. Proper sizing, combined with the modulating capabilities of Inverter technology, ensures the system runs for longer, steadier cycles, providing superior dehumidification and preventing inefficient short cycling.
Mini Split BTU Sizing & Application Guide
Use our quick reference chart to match your room size with the ideal system capacity.
| Capacity | Sq. Footage | Application |
|---|---|---|
| 6,000 BTU | 150–250 | Small bedrooms & offices |
| 9,000 BTU | 250–450 | Standard bedrooms |
| 12,000 BTU | 450–600 | Kitchens & studios |
| 18,000 BTU | 600–1,000 | Living rooms & garages |
| 24,000 BTU | 1,000–1,200 | Open floor plans |
| 36,000 BTU | 1,500–1,700 | Commercial & fitness |
| 48,000 BTU | 1,900–2,100 | Large warehouses |
| 60,000 BTU | 2,400–2,800+ | Commercial estates |
When to "Size Up"
If your ceilings are 10 feet or higher, you are cooling a larger volume of air. We recommend increasing your BTU choice by 20%.
For older homes or buildings with single-pane windows, opt for the next size up to ensure the unit can maintain the set temperature.
Appliances generate significant heat. If the unit is for a kitchen, add 4,000 BTUs to your square footage calculation.
Rooms with large south-facing windows or "sunrooms" act like greenhouses. Increase your BTU capacity by 10-15%
If the area regularly hosts more than two people (like a conference room or classroom), add 600 BTUs per additional person..
FAQs/Frequently Asked Questions
Q: Are ducted mini splits only for concealed installation?
A: No. While Concealed Ducted Units are designed to be hidden, the term "ducted mini split" also includes Air Handlers that might be installed in a utility closet or attic, replacing a traditional HVAC unit while using the existing ductwork.
Q: Can I connect multiple ducted units to a single outdoor condenser?
A: Yes. Many multi-zone outdoor condensers are flexible, allowing you to connect two or more ducted air handlers, or mix them with other indoor styles (like wall mount units) to optimize comfort and aesthetics across different zones.
Q: Are ducted systems more efficient than traditional central AC?
A: Typically, yes. Ducted mini splits use advanced inverter technology, allowing the compressor to modulate output and only consume the minimal energy necessary to maintain the set temperature. This results in significantly higher SEER ratings and energy savings compared to conventional fixed-speed systems.
Q: How do I size a ducted system for my home?
A: Ducted system sizing is more complex than single-room sizing and requires a Manual J load calculation to account for the total volume of all rooms, duct loss, insulation, and windows. We strongly recommend requesting a quote or using our technical support team for precise sizing.