Cooper&Hunter Single-Zone R454B, 6,000 BTU 230V Olivia Hyper Series Wall-Mount Air Conditioning Unit for Heat Pump, Mini Split Inverter System, 0.5 Ton 25.3 SEER2 with Wi-Fi, Optional Installation Kit - CH-R06MOLVWM-230VI + CH-RHP06F9-230VO
Vendor:Cooper&HunterRegular price $1,380.00Sale price $1,380.00 Regular priceUnit price per$701.66 -
Cooper & Hunter Slim Duct Hyper 12,000 BTU 230V R454B Concealed Duct Air Conditioning Unit for Heat Pump Mini Split Inverter System 21.4 SEER2 1 TON With Wi-Fi Enabled Thermostat & Optional Installation Kit CH-RS12MDT-MS + CH-RHP12-230V0
Vendor:Cooper&HunterRegular price $1,856.00Sale price $1,856.00 Regular priceUnit price per
wishlist
Welcome to the South Mini Splits collection for R454B Refrigerant. We feature high-efficiency systems from industry leaders like Cooper & Hunter, OLMO, MRCOOL, and Bravo.
These environmentally responsible, compliant, and high-performance units are the ideal solution for future-proofing your HVAC investment, meeting new regulatory standards, and significantly lowering your Global Warming Potential (GWP) impact.
๐กWhy Choose South Mini Splits for Your R454B Refrigerant?
โ Wholesale Pricing: Competitive rates on top-tier HVAC equipment.
โ USA-Based Support: Expert help from sizing to post-install troubleshooting.
โ Free Shipping Over $300: Get your complete system delivered fast.
What is R454B Refrigerant?
R454B is a new refrigerant blend designed to replace R410A in air conditioning and heat pump systems. It is categorized as a Hydrofluoroolefin (HFO) blend and is rapidly being adopted across the industry primarily because of its extremely low Global Warming Potential (GWP).
- GWP Advantage: R454B has a GWP of only 466, representing a 78% reduction compared to the older R410A refrigerant (GWP of 2,088). This compliance ensures your system meets new and pending EPA and CARB regulations aimed at reducing climate change impact.
- Near-Azeotropic Blend: This means the blend has properties very similar to a single-component refrigerant, which makes it easier to handle and charge than many other low-GWP alternatives.
- Performance: Systems utilizing R454B are engineered to provide performance equivalent to or better than R410A systems, ensuring you do not sacrifice cooling comfort or efficiency for environmental responsibility.
R454B Safety and Installation (Pro Insight)
As an A2L mild flammability refrigerant, R454B requires specific handling and awareness, making professional insight critical for customer confidence:
- A2L Classification: R454B is classified as A2L, meaning it has mild flammability. While far safer than highly flammable refrigerants, it necessitates that technicians follow strict safety protocols during installation, including proper ventilation and leak testing.
- New Equipment Required: R454B can only be used in HVAC systems specifically designed and listed for it. It cannot be used as a drop-in replacement for R410A systems due to differences in lubrication, component design, and safety features required for A2L refrigerants.
The "Future-Proof" Investment: Investing in an R454B system now protects you from future costs and headaches associated with phasing out higher-GWP refrigerants. By choosing R454B, you are installing a system designed to operate efficiently and comply with environmental standards for its full service life.
FAQs/Frequently Asked Questions
Q: Is R454B the only new refrigerant replacing R410A?
A: No, other low-GWP options like R32 are also being used. However, R454B is gaining significant traction due to its very low GWP and performance characteristics that make it highly suitable for mini split and residential applications.
Q: If R454B is mildly flammable, is my system safe?
A:Yes. Systems designed for R454B are engineered with multiple safety measures, including specialized leak sensors, controls, and construction that minimize any potential risk. The mild flammability classification means the refrigerant requires a significantly high energy source to ignite, making it safe for typical residential use.
Q: Can a standard HVAC technician install an R454B unit?
A: Technicians must have the proper training and tools for A2L refrigerants. While many licensed HVAC professionals are quickly adopting this training, it's essential to confirm your installer is certified to work with A2L refrigerants to ensure a compliant and safe installation.
Q: Will R454B systems cost more than R410A systems?
A: Initial costs may be slightly higher due to the advanced components and safety features required for A2L compliance. However, these systems are typically designed for higher efficiency, which can lead to significant energy savings over the lifetime of the unit, quickly offsetting any initial cost difference.
Q: What is the main environmental benefit of R454B?
A: The primary benefit is its extremely low Global Warming Potential (GWP of 466). Compared to R410A, which is over four times higher, R454B drastically reduces the climate impact of any potential refrigerant leak over the system's life.