Air handler units offer a versatile replacement for traditional air conditioning systems that can be connected to pre-existing duct work, but with smaller units that are quieter (variable speed fan motor) and more energy efficient. The air handlers, which are available in 18K, 24K, 36K, 48K, and 60K Btu/h models, can be installed vertically, horizontally, or downward. These units can be connected to any 24V wall thermostat and are compatible with standard 18K to 60K Btu/h outdoor models or Hyper Heat upgrades, which provide dependable heating in ambient temperatures as low as -22°F.
Models ranging from 36K to 60K Btu/h work for single zone applications, while 18K and 24K Btu/h are compatible with both single and multi zone condensers. Notable features include high static pressure and Quiet Operation.
Cooper & Hunter Single Zone Air Handler System (60,000 BTU)
Outdoor Unit: 60,000 BTU (1pc) – Model: CH-NHPR60LCU-230VO
Indoor Unit: 60,000 BTU (1pc with remote) – Model: CH-60AHU
Optional Installation Kit (16ft, 25ft, or 50ft options available) Must be selected above.
Optional Auxillary Heat Strip (5KW, 10KW, or 15KW, 20KW options available) Must be selected above.
Wi-Fi Enabled Thermostat
Wireless Remote Control
Installation Manual
User's Manual
Manufacturer Warranty
All units must be installed by a licensed HVAC professional for the warranty to be valid. Registration is required within 60 days of installation and can be completed online or by phone. The installation kit is necessary for the system to function. Ensure that you have selected the desired installation kit above. Visit https://cooperandhunter.us/warranty to register your product under Warranty, and call 786-953-6706 EXT 3 for This kit comes with Pre-Flared 99% Copper Lines, Data Communication Wires, PVC Drainage Attachment, Wrapping Bands, etc.
Model | SKU |
---|---|
18,000 BTU Air Handler with Optional Installation Kit 230V |
CH-M18AHU-W + CH-ES18-230VO |
24,000 BTU Air Handler with Optional Installation Kit 230V | CH-M24AHU-W + CH-ES24-230VO |
36,000 BTU Air Handler with Optional Installation Kit 230V | CH-36AHU-W + CH-N36LCU-230VO |
OLMO 36,000 BTU Air Handler with Optional Installation Kit 230V | OS-EAH36-230VI + OS-EAH36-230VO |
48,000 BTU Air Handler with Optional Installation Kit 230V | CH-48AHU + CH-N48LCU-230VO |
60,000 BTU Air Handler with Optional Installation Kit 230V |
CH-60AHU + CH-N60LCU-230VO |
HYPER Models | SKU |
---|---|
18,000 BTU Air Handler with Optional Installation Kit 230V |
CH-M18AHU + CH-HPR18-230VO |
24,000 BTU Air Handler with Optional Installation Kit 230V | CH-M24AHU + CH-HPR24-230VO |
36,000 BTU Air Handler with Optional Installation Kit 230V | CH-36AHU-W + CH-NHPR36LCU-230VO |
48,000 BTU Air Handler with Optional Installation Kit 230V | CH-48AHU + CH-N48LCU-230VO |
60,000 BTU Air Handler with Optional Installation Kit 230V |
CH-60AHU + CH-N60LCU-230VO |
Model | SKU |
---|---|
18,000 BTU Air Handler with Optional Installation Kit 230V |
CH-M18AHU-W + CH-ES18-230VO |
24,000 BTU Air Handler with Optional Installation Kit 230V | CH-M24AHU-W + CH-ES24-230VO |
36,000 BTU Air Handler with Optional Installation Kit 230V | CH-36AHU-W + CH-N36LCU-230VO |
OLMO 36,000 BTU Air Handler with Optional Installation Kit 230V | OS-EAH36-230VI + OS-EAH36-230VO |
48,000 BTU Air Handler with Optional Installation Kit 230V | CH-48AHU + CH-N48LCU-230VO |
60,000 BTU Air Handler with Optional Installation Kit 230V |
CH-60AHU + CH-N60LCU-230VO |
HYPER Models | SKU |
---|---|
18,000 BTU Air Handler with Optional Installation Kit 230V |
CH-M18AHU + CH-HPR18-230VO |
24,000 BTU Air Handler with Optional Installation Kit 230V | CH-M24AHU + CH-HPR24-230VO |
36,000 BTU Air Handler with Optional Installation Kit 230V | CH-36AHU-W + CH-NHPR36LCU-230VO |
48,000 BTU Air Handler with Optional Installation Kit 230V | CH-48AHU + CH-N48LCU-230VO |
60,000 BTU Air Handler with Optional Installation Kit 230V |
CH-60AHU + CH-N60LCU-230VO |
Specification | Details |
System Type | Single-zone unit |
BTU Rated | 60,000 BTU |
Power Source |
208-230V, 1Ph, 60Hz
|
Dehumidification Value | 12.93 pints/day |
Refrigerant Type | R410A |
Voltage Range (V) | 187-253 |
Packing Dimensions (W x D x H) |
27.95 x 26.77 x 56.50 inches
|
Controller |
RG10D standard remote & 120X or 120N wire controller
|
Refrigerant Piping (Liquid/Gas Side) | 3/8" - 7/8" |
EER2 | 10 |
SEER2 | 17 |
Unit Net/Gross Weight |
164.02 / 189.82 lbs
|
Unit Dimensions (W x H x D) |
21.02 x 24.49 x 52.99 inches
|
Operation Range - Heating | 32 ~ 86 °F |
Operation Range - Cooling | 60 ~ 90 °F |
Minimum Circuit Ampacity | 9A |
Max Fuse | 15A |
Indoor Noise Level H/M/L |
51 dB / 46 dB / 42.5 dB
|
Indoor Air Flow |
1,805.88 / 1,582.35 / 1,358.82 / 1,135.29 CFM
|
ESP Range | 0 - 0.8 |
Drainage Water Pipe Diameter | 1" |
Specification | Details |
System Type | Single-zone unit |
BTU Rated | 60,000 BTU |
Power Source |
208-230V, 1Ph, 60Hz
|
Dehumidification Value | 12.93 pints/day |
Max. Pipe Length | 213.25 ft |
Refrigerant Type | R410A |
Voltage Range (V) | 187-253 |
Packing Dimensions (W x D x H) |
43.11 x 19.49 x 58.27 inches
|
Refrigerant Piping (Liquid/Gas Side) | 3/8" / 7/8" |
HSPF2-5 | 7.5 |
HSPF2-4 | 9.2 |
EER2 | 9 |
Cooling Capacity (Min/Max) (BTU/h) |
55,000 (14,000 ~ 56,000)
|
SEER2 | 15.5 |
Unit Net/Gross Weight |
240.74 / 271.61 lbs
|
Unit Dimensions (W x H x D) |
37.48 x 16.34 x 52.48 inches
|
Refrigerant Precharge | 25 lbs |
Outdoor Noise Level | 62 dB |
Outdoor Air Flow | 4,235.29 CFM |
Minimum Circuit Ampacity | 44A |
Max Fuse | 60A |
Max Height Difference Between Indoor and Outdoor Unit | 98.42 ft |
Heating Capacity (Min/Max) (BTU/h) |
60,000 (13,400 ~ 69,000)
|
COP | 3.47 |
Ambient Temperature - Heating (°F) | -22 ~ 75 |
Ambient Temperature - Cooling (°F) | 5 ~ 122 |
Additional Refrigerant Charge (3/8" Liquid Line) | 0.32 lb/ft |
N 17 SEER Heat Pump Split System with Multi Position Air Handler Unit Including Optional Installation Kit and Optional Auxiliary Heat Strip
We will prepare your order within 24 hours if it’s received on a weekday (before noon). Orders are shipped in one to two business days. Transit time is between 3 to 6 business days, although exceptions apply. We email tracking information once your purchase is shipped.
IMPORTANT DELIVERY INFORMATION: Please be kindly informed that this air conditioner, due to its weight and shipping restrictions, is shipped palletized with an arranged freight service and requires an appointment for delivery. To AVOID delays, please check if the provided phone number in the order details is a current number where you can be reached. You can also contact the carrier directly and refer to your tracking number to set up a date and time for your appointment. It is your responsibility to ensure a safe and secure environment for delivery. Please note that we cannot be held liable for any packages that are stolen or lost after delivery has been confirmed. PLEASE verify your shipping address, as changes to the address after freight has shipped can result in an additional 15% or higher fee depending on freight weight and dimensions.
SMALLWARES INFORMATION: Please be informed that for smaller items, such as Installation Kits, Smart Connectivity Dongles, and TTW Sleeves, when these items are ordered individually, they may be shipped via FedEx without a signature requirement. It is your responsibility to ensure a safe and secure environment for delivery. Please note that we cannot be held liable for any packages that are stolen or lost after delivery has been confirmed. Thank you for your understanding and cooperation.
INSPECT YOUR MERCHANDISE BEFORE SIGNING: Please inspect your boxes thoroughly when you receive them. They should arrive shrink-wrapped and on a pallet. If you notice any damages or imperfections (e.g. crushed box or forklift hole), please write comments on the receipt before signing for delivery, no matter how small damages seem. Contact us immediately to assist you.