{"product_id":"cooper-hunter-30-000-btu-single-zone-outdoor-condenser-r-410a-ch-el30-230vo","title":"Cooper \u0026 Hunter EL Series 30,000 BTU Single-Zone Outdoor Condenser, R-410A, 208–230V – CH-EL30-230VO","description":"\u003cstyle\u003e\n  .sms-wrap{font-family:ui-sans-serif,system-ui,-apple-system,Segoe UI,Roboto,Ubuntu,Cantarell,Noto Sans,Helvetica Neue,Arial,\"Apple Color Emoji\",\"Segoe UI Emoji\";color:#0f172a;line-height:1.6}\n  .sms-container{max-width:1050px;margin:0 auto;padding:18px}\n  .sms-hero{display:grid;gap:10px;margin-bottom:18px}\n  .sms-title{font-size:28px;line-height:1.2;margin:0;color:#0b1220}\n  .sms-sub{font-size:16px;margin:0;color:#334155}\n  .sms-badges{display:flex;flex-wrap:wrap;gap:8px;margin:12px 0 4px}\n  .sms-badge{font-size:12px;border:1px solid #e2e8f0;border-radius:999px;padding:6px 10px;background:#f8fafc;white-space:nowrap}\n  .sms-grid{display:grid;grid-template-columns:1fr;gap:16px}\n  @media(min-width:900px){.sms-grid{grid-template-columns:1.2fr .8fr}}\n  .sms-card{border:1px solid #e2e8f0;border-radius:14px;padding:16px;background:#fff;box-shadow:0 1px 0 rgba(2,6,23,.04);margin-bottom:16px}\n  .sms-h2{font-size:20px;margin:0 0 8px;color:#0b1220}\n  .sms-h3{font-size:16px;margin:18px 0 6px;color:#0b1220}\n  .sms-list{padding-left:18px;margin:8px 0}\n  .sms-kv{display:grid;grid-template-columns:1fr 1fr;gap:8px}\n  .sms-kv div{padding:10px;border:1px solid #e2e8f0;border-radius:12px;background:#f8fafc;text-align:center}\n  .sms-table{width:100%;border-collapse:collapse;font-size:14px}\n  .sms-table th,.sms-table td{border:1px solid #e2e8f0;padding:10px;text-align:left;vertical-align:top}\n  .sms-table th{background:#f8fafc;width:32%}\n  .sms-note{font-size:12px;color:#475569}\n  .sms-alert{border:1px solid #fecaca;background:#fff1f2;color:#7f1d1d;border-radius:12px;padding:12px 14px}\n  .sms-ok{border:1px solid #bbf7d0;background:#f0fdf4;color:#14532d;border-radius:12px;padding:12px 14px}\n  .sms-resource{display:block;border:1px solid #e2e8f0;border-radius:12px;padding:11px 13px;margin:8px 0;background:#f8fafc;color:#0369a1;text-decoration:none;font-weight:600}\n  .sms-resource:hover{text-decoration:underline}\n\u003c\/style\u003e\n\u003cdiv class=\"sms-wrap\"\u003e\n\u003cdiv class=\"sms-container\"\u003e```\n\u003cdiv class=\"sms-hero\"\u003e\n\u003ch1 class=\"sms-title\"\u003eCooper\u0026amp;Hunter EL Series 30,000 BTU Single-Zone Outdoor Condenser – CH-EL30-230VO\u003c\/h1\u003e\n\u003cp class=\"sms-sub\"\u003eHigh-efficiency inverter outdoor condenser designed for a dedicated \u003cstrong\u003esingle-zone\u003c\/strong\u003e heating and cooling system. Delivers \u003cstrong\u003e30,000 BTU\u003c\/strong\u003e of rated capacity with up to \u003cstrong\u003e18.6 SEER2\u003c\/strong\u003e efficiency and must be paired with \u003cstrong\u003eone compatible R-410A indoor unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv class=\"sms-badges\"\u003e\n\u003cspan class=\"sms-badge\"\u003eEL Series\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003e30,000 BTU\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003e18.6 SEER2\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003eEER2 10.5\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003eR-410A Refrigerant\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003e208–230V, 1-Phase\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003eSingle Zone 1:1\u003c\/span\u003e \u003cspan class=\"sms-badge\"\u003eAHRI 207740529\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-grid\"\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eWhy customers choose this condenser\u003c\/h2\u003e\n\u003cul class=\"sms-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient inverter operation:\u003c\/strong\u003e Delivers up to \u003cstrong\u003e18.6 SEER2\u003c\/strong\u003e cooling efficiency for dependable comfort and improved energy performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU capacity:\u003c\/strong\u003e Designed for larger single-zone residential and light-commercial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating and cooling:\u003c\/strong\u003e Provides year-round operation with rated heating and cooling capacities of \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended piping capability:\u003c\/strong\u003e Supports refrigerant line lengths of up to \u003cstrong\u003e164.04 ft\u003c\/strong\u003e, subject to manufacturer installation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-zone simplicity:\u003c\/strong\u003e Dedicated one-to-one configuration provides individual comfort control for one room or area.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"sms-h3\"\u003eAt a glance\u003c\/div\u003e\n\u003cdiv role=\"list\" class=\"sms-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003cbr\u003e30,000 BTU\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003cbr\u003e18.6 SEER2\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003cbr\u003eSingle zone\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003cbr\u003eR-410A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eWhat’s included\u003c\/h2\u003e\n\u003cul class=\"sms-list\"\u003e\n\u003cli\u003e(1) Cooper\u0026amp;Hunter outdoor condenser: \u003cstrong\u003eCH-EL30-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation and available product resources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"sms-note\"\u003e\u003cstrong\u003eOutdoor unit only:\u003c\/strong\u003e Indoor unit, remote control, line set, electrical wiring, drain materials, mounting equipment, and installation accessories are sold separately unless specifically stated otherwise.\u003c\/p\u003e\n\u003cdiv class=\"sms-h3\"\u003eElectrical requirements\u003c\/div\u003e\n\u003cul class=\"sms-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 208–230V, 1Ph, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage range:\u003c\/strong\u003e 187–253V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum circuit ampacity:\u003c\/strong\u003e 23A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum fuse or breaker:\u003c\/strong\u003e 30A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eCompatibility — Single-Zone R-410A Systems\u003c\/h2\u003e\n\u003cdiv class=\"sms-alert\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e The CH-EL30-230VO is a \u003cstrong\u003esingle-zone outdoor condenser\u003c\/strong\u003e and supports a maximum of \u003cstrong\u003eone indoor unit\u003c\/strong\u003e. It should only be paired with a listed \u003cstrong\u003e30,000 BTU R-410A indoor unit\u003c\/strong\u003e.\u003c\/div\u003e\n\u003ch3 class=\"sms-h3\"\u003eCompatible wall-mounted indoor units\u003c\/h3\u003e\n\u003cul class=\"sms-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH-30ASTWM-230VI\u003c\/strong\u003e — 30,000 BTU Astoria Series Wall Mount, R-410A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH-30ELVWM-230VI\u003c\/strong\u003e — 30,000 BTU Olivia Series Wall Mount, R-410A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH-30ELSPHWM-230VI\u003c\/strong\u003e — 30,000 BTU Sophia Series Wall Mount, R-410A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"sms-ok\"\u003e\n\u003cstrong\u003eCorrect configuration:\u003c\/strong\u003e One CH-EL30-230VO outdoor condenser plus one compatible indoor unit listed above creates a complete single-zone system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eKey features\u003c\/h2\u003e\n\u003cul class=\"sms-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter-driven operation\u003c\/strong\u003e adjusts output based on changing comfort demands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18.6 SEER2 efficiency\u003c\/strong\u003e for energy-conscious cooling performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU rated cooling capacity\u003c\/strong\u003e with a variable output range of \u003cstrong\u003e7,200–31,600 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU rated heating capacity\u003c\/strong\u003e with a variable output range of \u003cstrong\u003e10,600–32,500 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-ambient cooling operation\u003c\/strong\u003e at outdoor temperatures as low as \u003cstrong\u003e5°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating operation\u003c\/strong\u003e at outdoor temperatures from \u003cstrong\u003e5°F to 86°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-line installation support\u003c\/strong\u003e with a maximum piping length of \u003cstrong\u003e164.04 ft\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-zone control\u003c\/strong\u003e for dedicated heating and cooling in one room or area.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eTechnical specifications — CH-EL30-230VO\u003c\/h2\u003e\n\u003ctable role=\"table\" class=\"sms-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eCH-EL30-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem type\u003c\/th\u003e\n\u003ctd\u003eSingle-zone outdoor condenser; maximum one indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRefrigerant\u003c\/th\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated capacity\u003c\/th\u003e\n\u003ctd\u003e30,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower source\u003c\/th\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage range\u003c\/th\u003e\n\u003ctd\u003e187–253V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSEER2\u003c\/th\u003e\n\u003ctd\u003e18.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEER2\u003c\/th\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHSPF2, Region IV\u003c\/th\u003e\n\u003ctd\u003e8.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHSPF2, Region V\u003c\/th\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCOP\u003c\/th\u003e\n\u003ctd\u003e2.71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling capacity\u003c\/th\u003e\n\u003ctd\u003e30,000 BTU\/h rated; 7,200–31,600 BTU\/h operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating capacity\u003c\/th\u003e\n\u003ctd\u003e30,000 BTU\/h rated; 10,600–32,500 BTU\/h operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5°F to 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5°F to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDehumidification\u003c\/th\u003e\n\u003ctd\u003e7.99 pints per day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiquid \/ gas pipe size\u003c\/th\u003e\n\u003ctd\u003e3\/8 in \/ 5\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum piping length\u003c\/th\u003e\n\u003ctd\u003e164.04 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum height difference\u003c\/th\u003e\n\u003ctd\u003e82.02 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory pre-charge line length\u003c\/th\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional refrigerant charge\u003c\/th\u003e\n\u003ctd\u003e0.32 oz per ft for installations using a 3\/8 in liquid line beyond the factory pre-charge allowance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum circuit ampacity\u003c\/th\u003e\n\u003ctd\u003e23A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum fuse \/ breaker\u003c\/th\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutdoor airflow\u003c\/th\u003e\n\u003ctd\u003e2,235.29 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutdoor noise level\u003c\/th\u003e\n\u003ctd\u003e60 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePacking dimensions\u003c\/th\u003e\n\u003ctd\u003e42.91 × 19.69 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet \/ gross weight\u003c\/th\u003e\n\u003ctd\u003e141.76 \/ 151.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAHRI reference\u003c\/th\u003e\n\u003ctd\u003e207740529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"sms-note\"\u003eRefrigerant line lengths beyond the factory pre-charge allowance may require additional refrigerant. Installation, evacuation, charging, electrical sizing, and startup should be completed according to the manufacturer’s instructions and applicable codes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eProduct resources\u003c\/h2\u003e\n\u003ca class=\"sms-resource\" href=\"https:\/\/media.cooperandhunter.us\/1136\/USER%27S-MANUAL-OUTDOOR-UNIT-18%2C000-BTU-%7E-48%2C000-BTU.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Outdoor Unit User Manual — 18,000 to 48,000 BTU \u003c\/a\u003e \u003ca class=\"sms-resource\" href=\"https:\/\/media.cooperandhunter.us\/3022\/CH-EL30-230VO-%2B-CH-30ASTWM-230VI.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Submittal — CH-EL30-230VO + CH-30ASTWM-230VI \u003c\/a\u003e \u003ca class=\"sms-resource\" href=\"https:\/\/media.cooperandhunter.us\/3758\/Astoria-leaflet2023.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Astoria Series Product Leaflet \u003c\/a\u003e\n\u003cp class=\"sms-note\"\u003eDocumentation may show a specific matched indoor unit. Confirm the selected indoor model, AHRI match, and installation requirements before purchasing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sms-card\"\u003e\n\u003ch2 class=\"sms-h2\"\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a complete mini-split system?\u003c\/strong\u003e\u003cbr\u003eNo. This listing is for the \u003cstrong\u003eCH-EL30-230VO outdoor condenser only\u003c\/strong\u003e. One compatible indoor unit and the required installation materials must be purchased separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this condenser operate more than one indoor unit?\u003c\/strong\u003e\u003cbr\u003eNo. It is a \u003cstrong\u003esingle-zone condenser\u003c\/strong\u003e designed to operate one compatible indoor unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich indoor units are compatible?\u003c\/strong\u003e\u003cbr\u003eCompatible wall-mounted indoor units include \u003cstrong\u003eCH-30ASTWM-230VI\u003c\/strong\u003e, \u003cstrong\u003eCH-30ELVWM-230VI\u003c\/strong\u003e, and \u003cstrong\u003eCH-30ELSPHWM-230VI\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be used with an R-454B\/R-32 indoor unit?\u003c\/strong\u003e\u003cbr\u003eNo. This model uses \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e and should only be paired with a compatible R-410A indoor unit approved for this condenser.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat electrical circuit is required?\u003c\/strong\u003e\u003cbr\u003eThe condenser requires a \u003cstrong\u003e208–230V, single-phase, 60Hz\u003c\/strong\u003e power supply, has a minimum circuit ampacity of \u003cstrong\u003e23A\u003c\/strong\u003e, and requires a maximum \u003cstrong\u003e30A\u003c\/strong\u003e fuse or breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow cold can it operate in heating mode?\u003c\/strong\u003e\u003cbr\u003eThe provided specifications list a heating operating range of \u003cstrong\u003e5°F to 86°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the AHRI reference number?\u003c\/strong\u003e\u003cbr\u003eThe provided AHRI reference is \u003cstrong\u003e207740529\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sms-note\"\u003eProduct specifications, approved combinations, documentation, and warranty terms may be revised by the manufacturer. Verify compatibility and current technical requirements before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n```\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":45288763850867,"sku":"CH-EL30-230VO","price":1435.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0134\/6709\/1044\/files\/REGULAR-24-36K.jpg?v=1785274343","url":"https:\/\/southminisplits.com\/products\/cooper-hunter-30-000-btu-single-zone-outdoor-condenser-r-410a-ch-el30-230vo","provider":"South Mini Splits","version":"1.0","type":"link"}